Bacteria in RO System
We received the following question on our web site:
"I am getting some bacteria coming out of my RO that I was not getting before. How can I clean the membranes."
Our Answer:
"You can use a product known as Minncare(R) or Oxonia. Both are sanitizing agents made up of hydrogen peroxide and peracetic acid. Dilute to 50 - 100 ppm, pump through RO, soak for an hour and rinse out. Please check with you membrane supplier and Minntech/Oxonia to insure compatibility with your RO membranes. Both Minncare and Oxonia are on the web."
"I am getting some bacteria coming out of my RO that I was not getting before. How can I clean the membranes."
Our Answer:
"You can use a product known as Minncare(R) or Oxonia. Both are sanitizing agents made up of hydrogen peroxide and peracetic acid. Dilute to 50 - 100 ppm, pump through RO, soak for an hour and rinse out. Please check with you membrane supplier and Minntech/Oxonia to insure compatibility with your RO membranes. Both Minncare and Oxonia are on the web."




0 Comments:
Post a Comment
<< Home